Designed with the professional in mind

Product is Available for Distribution in the US Only

On Call® Pro

Made specifically to address needs within the long-term care market

Optimal choice for healthcare professionals

510(k) cleared for multi-patient use, the On Call® Pro Blood Glucose Monitoring System is ideal for Long-Term Care due to its ease of use, user-friendly design, and large display with bold numbers. In addition, the time-saving meter features allow professionals to easily abide by their institution’s quality standards while providing the highest quality of care to patients.

Among the features that are included in the meter, the Daily Control Test Reminder feature was designed to help healthcare professionals in the long-term care market to abide by the quality standards upheld by their institution. When the feature is turned on, an alarm will go off if a control test has not been conducted in the past 24 hours. Additional features that improve the safety and usability of the system include a Ketone Test Alert and a Strip Ejector that reduces the risk of blood contamination.

Quick Facts



510(k) cleared for multi-patient use



CLIA-waived



Accuracy and reliability at an affordable price



Convenient Features



Strip Ejector prevents contact with contaminated test strips



Daily Control Test Reminder easily ensures adherence to quality measures

On Call® Pro

Product Features

N

Fast and Reliable

  • Tiny 0.4 µL sample size
  • 4 seconds to result
  • Clinically proven accuracy
  • Audible fill detection reduces wasted strips



Premium Professional Features

  • Daily Control Test Reminder
  • Hypo and hyper alarms
  • Ketone test alert



Easy to Use

  • User friendly design
  • Large display with bold numbers
  • Strip port faces the patient
  • Convenient test strip ejector reduces risk of contamination

On Call® Pro

Frequently Asked Questions

What is the Daily Control Test Reminder?

The Daily Control Test Reminder is a feature developed specifically for the long-term care market. It acts as a QC Lockout to remind the blood glucose meter operator to conduct a control test every 24 hours. If a control test has not been performed in a 24-hour period, a Daily Control Test Reminder alarm will occur as a flashing “Ctl” symbol on-screen along with the clock symbol and the control test symbol.

As a precautionary measure, please ensure that no patient blood sample is tested while the Daily Control Test Reminder is occurring. The results will be marked as a control.

How do I turn on/off the Daily Control Test Reminder?

Press and hold the right arrow button (►) to enter the Meter Setup. Scroll through the various options until you reach a screen that says “On” or “Off” and displays the “Ctl” symbol at the top of the screen, a clock symbol at the right of the screen, and the Control Solution symbol. Press the left arrow button (◄) to change between “On” or “Off” and then press the right button (►) to confirm your selection. Scroll through the remaining meter setup options. The Control Test Reminder will occur after 24 hours if no control test has been conducted.

Can I use a lancing device and lancets when operating the On Call® Pro Blood Glucose Monitoring System?

Only single-use auto disabling safety lancets should be used with the On Call ® Pro Blood Glucose Monitoring System.

What type of disinfection wipes can I use to disinfect the On Call® Pro meter?

The On Call ® Pro Blood Glucose Monitoring system is currently validated for use with the DisCide Ultra Disinfecting Towelettes and the Super Sani-Cloth Germicidal Disposable Wipes (PDI). Please see the On Call ® Pro User Manual for more information on proper cleaning and disinfecting procedures using these materials. Please do NOT use any product containing bleach on the blood glucose meter as it will void the product warranty and may cause damage to the meter.

Is there any interference from Maltose or Icodextrin which may result in risk for patients undergoing Dialysis?

The On Call ® Pro glucose monitoring system uses the glucose oxidase enzyme to detect glucose, therefore there is no interference from maltose or Icodextrin. The On Call ® Pro system is safe for use on patients undergoing dialysis but is not for use on critically ill patients.

Is the On Call® Pro Blood Glucose Monitoring System designed for hospital use?

The On Call ® Pro does not include the ability to scan patient ID barcodes so that records for multiple patients may be kept separate and distinct on the same meter. Additionally the On Call ® Pro is only validated for testing capillary whole blood from the fingertip, palm or forearm. It should not be used for testing venous, arterial or neonatal blood.

Is the On Call® Pro suitable for self-testing?

No, the On Call ® Pro is intended for professional use only. For available glucose monitoring systems which are intended for self-testing, please visit www.oncallmeters.com.

Is data management software available for use with the On Call® Pro?

The On Call ® Pro is intended for multi-patient testing and does not have the ability to scan a barcode to differentiate between each individual patient within a software platform. The On Call ® Pro was designed for use in a multi-patient setting where glucose readings are recorded immediately after conducting a blood glucose test. It was not designed for use with software.

On Call® Pro

Product Specifications

Feature Specification

Enzyme Glucose Oxidase

Measurement Range 20-600 mg/dL

Result Calibration Plasma-equivalent

Minimum Sample Size 0.4 µL

Test Time 4 seconds

Battery Life 1,000 tests

Memory Up to 300 records with date and time

Automatic Shutoff 2 minutes after last action or 5 sec after strip removal

Meter Size 85 x 40 x 16.4 mm

Display Size 35 mm x 32 mm

Operating Temperature 41-113˚F (5-45 ˚C)

Operating Relative Humidity 10-90% (non-condensing)

Hematocrit Range 25 – 60%

  • Paiement en espèces à la livraison
  • Livraison partout en Tunisie
Demander ce produitNous le commandons auprès de la marque et vous rappelons avec son prix.
Paiement à la livraison · Livraison partout en Tunisie
Demander ce produit

Note : Tous les produits parapharmaceutiques et paramédicaux, ainsi que les marques non encore disponibles sur notre site, peuvent être commandés sur demande, sous réserve de leur conformité et de leur certification en Tunisie.

Demander un produit

Note : Tous les produits parapharmaceutiques et paramédicaux, ainsi que les marques non encore disponibles sur notre site, peuvent être commandés sur demande, sous réserve de leur conformité et de leur certification en Tunisie. Demander un produit

Produits associés

Produits associés

STERILANCEBionime Sterilance Soft Lancette B/100
12,852 DT100 lancettes
STERILANCESTERILANCE LANCETTES BOITES DE 50
5,880 DT50 lancettes
STERILANCESteriLance Twist - Lancettes stériles - calibre 30 - B/100 lancettes
16,000 DT
STERILANCESTERILANCE Lancette stérile Press II
24,900 DT100 lancettes
Camouflage ParaclinicParapharmacieet soins à domicile.
BoutiqueAdulteBébé & EnfantAnimauxEquipement Médical
ServicesInfirmerie MobileIonophorèseEpilation Aisselles IPLMicrodermabrasionSemelles sur mesureStretch marks LiftBeauty SkinEye LiftCures minceurConsultation en ligneLivraison à domicile
AideContactMon compteSuivi de commandeLivraisonPolitique de retourCGVMentions légalesConfidentialitéCookies
© 2026 Camouflage ParaclinicSite conçu et développé par Zelos.tn · +216 24 612 208
LivraisonContactSuivi de commandeMon compte
CGVPolitique de retourMentions légalesConfidentialitéCookies
© 2026 Camouflage ParaclinicSite conçu et développé par Zelos.tn · +216 24 612 208

Cookies

Nous utilisons uniquement les cookies nécessaires au site : panier, compte, langue. Détails et préférences

AccueilBoutiqueSoinsPanier